+86 156 1770 3811 Mobile Phone

8615617703811 Whatsapp

+86 156 1770 3811 Wechat

admin@cnhuaer.com E-mail

Dental Handpiece

Low Speed Handpiece Set

Low-speed dental handpiece sets, affordable, quality assurance, to meet the needs of dentists for polishing, polishing and treatment, external or built-in waterways optional.

Product Details

Dr.Super Low-speed dental handpieces set include motors, straight handpiece and contra angle, mainly for dental grinding, model grinding and treatment.

low-speed-handpiece-set-6.jpg


----Quiet, low vibration. High torque 18,000rpm/min motor with swivel connector reduces tubing drag.

----Lightweight, comfortable, ergonomic grip makes medical staff easier to operate

----Quick connector easy to insert, easy to disinfect, reduce the workload


Product Specification

Contra angle

Operation Air Pressure0.3Mpa-0.35Mpa

Rotor Speed

≥18(krpm/min)

Air Pressure0.3Mpa-0.35Mpa
Noise≤70dB


Straight handpiece

Operation Air Pressure0.3Mpa-0.35Mpa

Rotor Speed

≥18(krpm/min)

Air Pressure0.3Mpa-0.35Mpa
Noise≤70dB
SprayExternal single spray


Instructions

First, use a dental handpiece

1. Need to use a clean, dry, oil-free medical air compressor;

2. The air pressure is between 2.3-2.8kgf / cm2;

3. Combine the quick connector with the adapter on the bottom of the handpiece and confirm that it is locked;

4. Depress the pedal to see if the dental handpiece is operating and the nasal spray is operating normally. If everything works, you can start using your dental handpiece.


Maintenance

It is very important to take latch angles apart for proper lubrication. If you are processing angles routinely, at least once a day unscrew the head from the sheath and remove the transmission gear for cleaning and oiling (try doing this first thing in the morning as part of the opening routine). Apply a drop of oil under each gear on the transmission gear as well as in the center hole. Apply several drops of oil to the exposed cartridge while the transmission gear is removed.

 

Something you need to know

Water supply problem

(1) Insufficient water supply.

(2) The amount of water is not uniform.

(3) The water supply will not be thinned.

(4) There is no water at all.


Solution: Check the location of water blockage

(1) Pipeline: Remove the turbine handpiece and check if there is a proper amount of water in the pipe. If no water flows out, it may be a problem with the water supply system of the water pipe or the integrated treatment station (poor contact or misoperation, insufficient water pressure at the source).

(2) Interface: Test interface connection wires. If you don't get the right amount of water, this is an interface problem (scale, etc., clogging the water supply system or loose connectors, resulting in insufficient pressure).

(3) Dental handpiece body: After removing the shaft from the turbine, install the interface for operation. If there is not a proper amount of water flowing out, there is a problem in the turbine body (the water supply hole is blocked by dust or the water supply system in the turbine is blocked).

(4) Axial core: If the above three kinds of water supply flow out normally, it is the problem of the axial core (plugging of the water supply nozzle).

 

 

 


Certification

  • Certification

  • Certification

  • Certification

  • Certification

  • Certification

  • Certification

Inquire Us Now

Get Wholesale Pricing

Complete the fields below to receive more private label information

Huaer Group 24*7 at your service, WhatsApp number: +86 156 1770 3811

8615617703811

WhatsApp

WeChat

admin@cnhuaer.com

E-mail
Inquire Now Catalog