E-Generator Integrated LED Dental Handpiece
E-generator integrated LED dental handpiece meet the dentist's need for light intensity, lightweight experience, ergonomic handle, allowing users to work easily. Cost-effective quality reduces medical costs, but E-generator integrated LED dental handpiece also provides excellent service for patients.
Product Details
From the perspective of users, Dr.Super E-generator integrated LED dental handpieces are designed with ergonomic handles and stable power drive structures with 20000 Lux illumination to meet the needs of medical personnel and provide professional treatment for patients.
----Illumination intensity reaches 20000 Lux, expand the visible area in the mouth, reduce the difficulty of medical staff
----Triple spray design makes the patient more comfortable in the treatment process
----Lightweight, comfortable, ergonomic handles make it easier for medical staff to work
----Increased visual area to assist medical personnel to operate more efficiently
----Button design for easy bur replacement
Product Specification
Operation Air Pressure | 0.25-0.30MPa(0.25MPa preferred) |
Rotor Speed | ≥350(krpm)for Standard head; ≥280 (krpm) for torque head |
Grip Power | 25-45N |
Water Pressure | 0.2Mpa (2Kgf) |
Water flow | 90(min/ml)-110(min/ml) |
LED Luminous Intesity | ≥16000LUX |
Temperature | 3500(K)-4000(K) |
Spray | triple spray |
Standard Features:
1. Open cartridge, easily for maintenance
2. Anti-retraction function design, protect patients from cross infection, extend lifespan for the handpiece
3. 135℃ autoclavable for the handpiece
4. Dynamic balance inspection technology, low noise during operation, extend lifespan for the bearing
Bearing Maintenance
Bearing damage ---- Bearing is an important part of the head, reducing bearing wear can extend the life
1.When the bur is blunt, the grinding efficiency is reduced, and new burs must be replaced in time, otherwise the bearing life will be affected.
2.When the number of patients is high and the patient's enamel is too hard, the holes for various types of burs should be properly used. When the drill is used, it is preferable to use a translational rotary motion. Do not fix it at a point.
3.When the bur is initially moved and the rotational speed has not yet reached the maximum speed, the teeth are drilled so that the bearing is subjected to excessive force. Should make the bur rotation speed reach the maximum rotation speed, then touch the tooth body to drill.
After-sale Warranty
We guaranty each handpiece will be tested strictly before ship to clients. And we promise to repair each handpiece if it's faulty.